Intelligent Solutions Group International globe logoIntelligent Solutions GroupInternational

FACTORY-DIRECT POWER EQUIPMENT

Energize your next
project.
Intelligently.

Put factory-direct sourcing to work for your schedule and budget. ISG coordinates equipment design, manufacturing and delivery around your specifications, helping simplify procurement and prepare your project for energization.

ISG letterforms on a globe

CANADA FRANCE GERMANY UNITED KINGDOM UNITED STATES

Custom power equipment, designed and manufactured to your specifications.

Factory Direct. Premium Quality. Energized Sooner.

Factory direct.
Built to your specifications.

500 MVAEHV power transformers
6,000 ALow-voltage switchboards
34.5 kVMedium-voltage switchgear

01 / PRODUCT PORTFOLIO

Explore the equipment behind the application.

The right equipment.
Built for your project.

Find the equipment that fits your application. Compare configurations, review the source specifications and download an individual data sheet.

11 product families
Which equipment fits your application?

Transformers

Compare liquid-filled EHV, generator step-up and pad-mounted configurations with cast-resin or VPI dry-type options.

Distribution & controls

Switchboards and panelboards distribute power. Motor control centers and industrial control panels support motor and process applications.

Containerized Solutions

Coordinate transformer and distribution equipment in a project-specific skid, E-house or integrated package.

Medium-Voltage Switchgear product example
SWITCHGEAR & CONTROLS

Medium-Voltage Switchgear

15 / 34.5 kV classes / up to 4,000 A

Air-insulated medium-voltage switchgear with draw-out vacuum circuit breakers.

IEEE C37.20.2 / UL / CSA

Data sheet
EHV Power Transformers product example
TRANSFORMERS

EHV Power Transformers

Up to 500 MVA / 345 kV class

Power transformers for transmission, grid interconnection, and substation reinforcement.

IEEE / ANSI / IEC

Data sheet
Pad-Mounted Transformers product example
TRANSFORMERS

Pad-Mounted Transformers

Up to 10 MVA / 36 kV class

Distribution transformer configurations for commercial facilities, EV charging, solar, and battery storage.

ANSI / IEEE / CSA / DOE

Data sheet
Low-Voltage Switchboards product example
SWITCHGEAR & CONTROLS

Low-Voltage Switchboards

Up to 6,000 A / 480 or 600 V

Low-voltage distribution switchboards with configurable protection, bus construction, and monitoring.

UL 891 / CSA

Data sheet
Panelboard and Remote Power Panel examples, with main and branch breakers and metering
SWITCHGEAR & CONTROLS

Panelboards

Up to 1,200 A / 480 or 600 V

Low-voltage panelboards for commercial, industrial and Data Centers, including project-specified Remote Power Panel (RPP) applications.

UL 67 / CSA

Data sheet
Cast-Resin Transformers product example
TRANSFORMERS

Cast-Resin Transformers

300 kVA to 15 MVA / up to 36 kV

Dry-type transformer options for indoor and critical-space power distribution.

UL / IEEE / IEC

Data sheet
Internal dry-type transformer installation
TRANSFORMERS

VPI Transformers

100 to 5,000 kVA / up to 36 kV

Vacuum pressure impregnated dry-type transformers with application-specific thermal classes.

UL / IEEE / IEC

Data sheet
Industrial Control Panels product example
SWITCHGEAR & CONTROLS

Industrial Control Panels

Up to 600 V / PLC and automation control

PLC and automation control panels for industrial process and equipment applications.

UL 508A / CSA

Data sheet
Motor Control Centers product example
SWITCHGEAR & CONTROLS

Motor Control Centers

Up to 3,000 A / 480 or 600 V

Draw-out intelligent motor control centers with configurable drive integration and motor protection.

UL 845 / CSA

Data sheet
Green containerized power equipment module with open equipment bays, transformer coils and switchgear
CONTAINERIZED SOLUTIONS

Containerized Solutions

Integrated containerized power equipment packages

Project-specific containerized power equipment packages with transformer and distribution equipment, structural fabrication and electrical integration.

Equipment-specific standards

Data sheet

Need a different voltage, enclosure or configuration? Send us your specifications. Final ratings, listing scope and delivery are established in the manufacturer’s quotation and technical submittal.

CUSTOM DESIGN & MANUFACTURING

Designed for your project.
Manufactured to your specifications.

Tell us the ratings, footprint, enclosure and operating requirements you need. We coordinate the design and manufacturing scope with our factory partners, from a single unit to a coordinated power equipment package.

Discuss your custom design

DON’T LET PROCUREMENT SET THE PACE

Plan your schedule.
Confirm factory availability.

For projects in the U.S., Canada, the U.K. and worldwide, start with the equipment scope and required date. A current quotation establishes the available production slot and delivery responsibilities.

SUPPLIER-PUBLISHED FACTORY ESTIMATES
16–18 weeks EXWPad-mounted transformers
32–34 weeks EXWGenerator step-up transformers
42–46 weeks EXWEHV power transformers

Supplier brochure estimates, subject to configuration and current factory capacity. The quotation confirms the schedule start, named EXW pickup point and logistics responsibilities. Freight, site delivery and commissioning require separate scope. Request your project schedule ↗

02 / STANDARDS & CERTIFICATIONS

Product-specific requirements. Clear documentation.

Confidence starts
with the details.

Match the equipment to the standard your project requires. Review the supplier’s published listings, standards and enclosure classifications by product.

UL 891LV switchboards
UL 508AIndustrial control panels
UL 845Motor control centers
UL 67Panelboards
View all product standards and certification details
Product familySupplier-published standards and certifications
EHV Power TransformersIEEE C57.12.00 / C57.12.90; ANSI C57.12.10; IEC 60076. Partial-discharge testing references IEEE C57.113; coating options reference IEEE C57.12.28.
Pad-Mounted TransformersIEEE C57.12.90. Supplier references ANSI / IEEE / CSA / DOE compliance.
Low-Voltage SwitchboardsUL 891; CSA; ANSI; NEMA. Supplier states UL Listed / CSA Listed compliance; UL file E541160. NEMA 1 / 12 / 3R options.
Medium-Voltage SwitchgearIEEE C37.20.2; ANSI C37 design references. Supplier states UL / CSA Type Tested. NEMA 1 / 3R options.
Generator Step-Up TransformersIEEE C57.12.00 / C57.12.90; IEC 60076. Applicable efficiency requirements, insulating fluid and spill-containment provisions are confirmed for the selected design and site.
PanelboardsUL 67; CSA; ANSI; NEMA. Supplier states UL Listed. NEMA 1 / 12 / 3R / 4X options.
Cast-Resin TransformersUL Listed; IEEE C57.12.01; IEC 60076-11. Source lists F1 fire behavior, C1 / C2 / C3 climate and E2 humidity classes.
VPI TransformersThe shared CRT / VPI product page references UL Listed; IEEE C57.12.01; IEC 60076-11; ANSI / IEEE / CSA / DOE. Confirm classifications for the selected VPI design.
Industrial Control PanelsUL 508A; CSA. Supplier states UL Listed; UL file E50611. NEMA 1 / 12 / 3R / 4X options.
Motor Control CentersUL 845; CSA. Supplier states UL Listed. NEMA 1 / 12 enclosure options.
Containerized SolutionsSupplier scope lists IEC / IEEE / UL / CSA / DOE transformer references and IP64 / IP65 or fire-rated enclosure options. Confirm the selected equipment’s certifications, applicable efficiency requirements, enclosure test reports and complete-package acceptance requirements.

Standards references and supplier listing claims are shown by product. Request current manufacturer listing documentation, test reports and the applicable standard edition for the selected configuration. Enclosure and component ratings have their own evaluation scope.

03 / FROM SPECIFICATION TO SUPPLY

From specification
to shipment.
Keep the project moving.

Review equipment scope, factory pricing and production availability in one conversation. We align design approvals, manufacturing and shipment with your installation milestones, so you can assess cost and schedule together.

  1. 01

    Define the equipment

    Share your single-line diagram, ratings, quantity and site conditions. We align the configuration with your load, application and required standards.

  2. 02

    Get factory-direct pricing

    Review the equipment scope, technical submittal and commercial terms with a direct path to our manufacturing partners.

  3. 03

    Secure the production schedule

    Confirm factory availability, approval milestones and logistics. Establish a realistic delivery plan that supports your target energization date.

04 / MICROGRIDS & RESILIENCY

More control.
Resiliency by design.

Coordinate the power. Protect the operation.

Coordinate utility power, onsite generation, battery storage and controls around critical loads and operating priorities. ISG aligns electrical equipment requirements with your engineering and controls partners.

A COORDINATED POWER SYSTEM

Utility power.
Generation. Storage.
Coordinated controls.

Define the electrical boundary and the equipment interfaces together. The design determines how the resources operate as a system.

Microgrid equipment concept rendering from the ISG image review sheet, showing a fenced behind-the-meter site with transformer, switchgear, generation and modular power equipment
Illustrative behind-the-fence microgrid equipment layout. Project engineering defines the final configuration.
Discuss a microgrid application Explore a microgrid equipment layout
01 / ELECTRICAL FOUNDATION

Connect and protect

Transformers, switchgear, protection and distribution equipment establish the path from each power source to the site’s loads.

02 / CONTROL & OPTIMIZATION

Microgrid controls, EMS & DERMS

A microgrid controller coordinates local resources and operating modes. An energy management system (EMS) schedules resources around demand, cost and reserve priorities. A distributed energy resource management system (DERMS) can coordinate distributed assets with broader grid requirements.

03 / OPERATIONAL RESILIENCY

Plan for the interruption

Establish critical-load priorities, reserve duration, protection coordination and recovery sequences. Islanded operation requires a suitable system design, utility coordination and commissioning.

Critical-load planning

Size resources around the loads that must stay operational.

Energy flexibility

Coordinate generation, storage and controllable demand.

A practical path to power

Align equipment and controls with phased site requirements.

Transfer behavior, operating duration and recovery targets depend on project engineering, available resources and commissioning. Confirm protection, controller interfaces and integration responsibilities in the project scope. Microgrid technical context: U.S. Department of Energy ↗

EFFICIENCY & LIFECYCLE PERFORMANCE

Better decisions begin with operating data.

Efficiency you
can measure.

Evaluate power equipment against the way your site will operate. Request evidence for energy performance and consider operating cost alongside the equipment price.

01 / EQUIPMENT PERFORMANCE

Ask for the loss data.

Request tested transformer no-load and load losses, stated test conditions and auxiliary power requirements. Compare the selected design against your expected site load profile.

02 / WHOLE-LIFE VALUE

Look beyond purchase price.

Consider installation, projected loss energy, maintenance, replacement assumptions and end-of-life responsibilities. Confirm who provides the analysis and supports the installed equipment.

03 / DISPATCH PRIORITIES

Balance operating objectives.

Cost, emissions and backup reserves can call for different resource schedules. Define your priorities with the controls and engineering team. Quantify outcomes against a clear baseline.

Environmental performance depends on the equipment, energy sources and operating schedule. Request documented assumptions for any savings or emissions claim. No universal savings or carbon reduction is assumed.

Discuss your performance requirements

05 / POWER FOR YOUR APPLICATION

Start with the application.

From the utility
to the load.

Data Centers. Renewable energy. Fleet charging. Industrial operations. Source the core electrical equipment that connects available power to the work your site needs to do.

Power equipment example for data centersPRODUCT EXAMPLE

EQUIPMENT FOR YOUR APPLICATION

Data Centers

Transformers and distribution equipment for new development, existing facilities and phased capacity expansion.

Discuss your application

06 / WARRANTY & OPERATING SUPPORT

Plan for the life of the equipment.

Downtime is costly.
Support belongs in the plan.

Product warranty support and operations and maintenance packages are offered alongside equipment procurement. Define the coverage your site needs before the equipment enters service.

PRODUCT WARRANTY

Know your coverage.

Review manufacturer warranty terms, the coverage start, parts and labor, exclusions and the claim process with your quotation. Confirm the provider and responsibilities for the selected equipment.

Discuss warranty coverage

OPERATIONS & MAINTENANCE

Plan for availability.

Ask about an O&M package aligned with the installed equipment, operating environment and site priorities. Establish the preventive maintenance scope, service intervals and support responsibilities in your proposal.

Discuss an O&M package

Warranty and O&M packages are offered for the selected equipment and project. Request the service provider, geographic coverage, maintenance duties and response commitments in the applicable agreement.

07 / INTELLIGENT SOLUTIONS GROUP INTERNATIONAL

A passion for power.
Integrity in every solution.

Serving customers across the globe with factory-direct, advanced power equipment built around their specifications.

Intelligent Solutions Group International is built on honesty, integrity and prompt service. We listen to what your project needs, communicate clearly and connect you with manufacturing partners who can meet the specification.

Intelligent thinking.

Understand the need. Explore better configurations. Align power equipment with the way your site operates.

Solutions that simplify.

Reduce procurement and installation complexity through clear specifications, coordinated equipment and a practical delivery plan.

Group strength. Global reach.

Connect customers with manufacturing partners across international markets, with one focused commercial relationship.

ISG INTERNATIONAL

ISG-color world map with star markers for the United States, Canada, France, Germany, and the United Kingdom

★ United States   ★ Canada   ★ France   ★ Germany   ★ United Kingdom

WORLD MARKETS

Supporting projects worldwide.

Markets served: the United States, Canada, France, Germany and the United Kingdom. ISG coordinates equipment specifications, factory supply and delivery requirements for projects across these markets.

  • United States
  • Canada
  • France
  • Germany
  • United Kingdom

08 / PRODUCT DATA SHEETS

Details for your next project conversation.

The specifications.
Within reach.

Specifications, features and standards for every product family, in a consistent format ready for your engineering and procurement teams.

View all product data sheets Download individual PDFs as a ZIP
What to include in a project inquiry
  • Equipment type, quantity, and application
  • Required kVA / MVA, voltage, amperage, and fault rating
  • Single-line diagram or equipment schedule, if available
  • Site location, installation environment, and enclosure needs
  • Required standards, certifications, and target delivery date
How are specifications and delivery confirmed?

We review your requirements with the supplying manufacturer. The final quotation and technical submittal establish the selected configuration, applicable certifications, scope, and delivery schedule.

What should a technical proposal establish?
  • Equipment ratings, quantity, installation environment and required standards
  • Current listing scope and applicable factory test reports
  • Protection, utility and controls integration responsibilities
  • Factory schedule milestones, named shipping point and site-delivery responsibilities
  • Warranty start, coverage, service provider and O&M scope

GET A FACTORY-DIRECT QUOTE

Your requirements.
Our next conversation.

Share the equipment type, quantity, required ratings and site-delivery date. Include your specifications, equipment schedules or drawings with your quotation request.

sales@isg-intl.com
What would you like to discuss?

The email draft does not carry files automatically. Attach your selected files in your email app before sending.

CAREERS AT ISG INTERNATIONAL

Bring your market knowledge.
Help power what comes next.

Commercial and technical opportunities in Canada, France, Germany and the United Kingdom.

Explore careers
ISG / PRODUCT INFORMATION