Cast-Resin Transformers

Dry-type transformer options for indoor and critical-space power distribution.

Cast-Resin Transformers product example

Representative configuration

APPLICATION & CONFIGURATION

Where it fits

Consider cast-resin transformers for indoor and critical-space distribution projects where oil-free construction and specified environmental classes guide selection.

  • Oil-free transformer construction
  • Low partial-discharge insulation design
  • Harmonic and K-factor options for nonlinear loads
  • Configurations for occupied and critical spaces

ApplicationsData centers, hospitals, marine facilities, renewable energy, industrial distribution

SUPPLIER-PUBLISHED PRODUCT INFORMATION

Technical specifications

Full source table reproduced from supplier brochure page 9. Confirm the selected configuration in the approved project submittal.

RATING300KVA - 15 MVA
VOLTAGEupto 36kV
COOLINGAN / ANAF
CLASSF1 – fire behaviour C1, C2 & C3 – Climate E2 – condensation & humidity
LEAD TIME16 — 18 weeks EXW

Standards & certification scope

UL Listed; IEEE C57.12.01; IEC 60076-11. Source lists F1 fire behavior, C1 / C2 / C3 climate and E2 humidity classes.

The source table states 16–18 weeks EXW; accompanying narrative states 14–16 weeks. Confirm the current factory schedule with your quotation.

Supplier-published configurations. Confirm the selected ratings, dimensions, applicable standards and listing scope in the project quotation and technical submittal.

PROJECT TIMING & QUALITY

Move from specification to schedule.

Factory-direct coordination keeps equipment scope, pricing and production planning connected. Share your required site-delivery date and energization milestone early so ISG can coordinate the selected configuration, available factory slot and shipment plan.

Quality is specified and documented: confirm applicable standards, inspection, routine testing and warranty coverage in the manufacturer’s quotation and approved technical submittal. Lead time is confirmed for the selected configuration and current factory schedule.

Share your project timeline

A STRONGER REQUEST FOR QUOTATION

What should the
factory review?

Send the available requirements. We’ll identify what still needs confirmation.

  • What quantity, kVA or MVA rating, primary and secondary voltages and cooling arrangement are required?
  • Which fire-behavior, climate and humidity classes, harmonic-duty requirements and listing documentation are specified?
  • What site-delivery date is required so the factory can confirm its current schedule against the differing brochure estimates?
Discuss this configuration